Compare Products

Hide

Clear All

VS

Picture

RG-S6920-4C – Next-Generation Data Center 100GE Switch with 100GE/400GE Line Cards

Compared with the traditional networking with modular core switches, the entire network with RG-S6920-4C switches uses the Clos architecture, reducing the TCO by 25% and power consumption by 31%. Furthermore, RG-S6920-4C switches help build stable and lossless networks.

Models
Series
Highlight Features
  • Diverse ports, four service slots, up to 128 x 100GE QSFP28 ports or 64 x 100GE QSFP28 and 16 x 400GE QSFP-DD ports

  • Hardware-level redundancy, ensuring service continuity

  • Lossless Ethernet, ensuring zero packet loss during RDMA E2E communication

  • Telemetry-based network monitoring and automated O&M, making management simple and efficient

  • Highly-efficient heat dissipation and energy saving, with power consumption less than 1950 W and power conversion efficiency up to 94%

Sales Enquiry
Features

Data Center 100GE Core Switch RG-S6920-4C

Four service slots, with 100GE and 400GE line cards, allowing for easy expansion and satisfying future bandwidth expansion needs
Various ports, up to 128 x 100GE ports or 64 x 100GE ports and 16 x 400GE ports, which are fit for different scenarios of data center networks

Hardware-level Redundancy, Ensuring Service Continuity

Hot-Swappable Redundant Power Modules

Hot-Swappable Redundant Fan Modules

Power modules in 2+2 redundancy mode, failover in seconds, and power module replacement without
network interruption, providing double protection for links

Lossless Ethernet with RDMA E2E Communication
and Zero Packet Loss

With RDMA technology, data does not need to be handled by the CPU during device communication. This reduces the CPU burden
and effectively solves the network latency problem.
PFC+ECN, intelligent data exchange, and packet loss prevention, ensuring lossless data transmission

Telemetry-based Network Monitoring and Automated O&M,
Making Management Simple and Efficient

The switch enabled with telemetry provides clear data status and hierarchy.
The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time,
making network management more efficient and accurate.

Specifications

Hardware Specifications

System Specifications

RG-S6920-4C

Ports

100GE/400GE ports

Expansion Module Slots

Four expansion module slots, each supporting the line card with up to 32 × 100GE ports

Expansion Modules

Four power supply modules

Six fan modules

Management Port

One management port, one console port, and one USB port, compliant with the USB2.0 standard

Switching Capacity

25.6 Tbps

Packet Forwarding Rate

8000 Mpps

802.1Q VLAN

4094

Dimensions and Weight

RG-S6920-4C

Dimensions
(W × D × H)

442 mm x 735 mm x 173.6 mm (17.40 in. x 28.94 in. x 6.83 in., 4 RU)

Weight

About 34.25 kg (75.51 lbs., including all line cards, power supply modules, and fans)

Power Supply and Consumption

RG-S6920-4C

Maximum Power Consumption

● Max: 1950 W

● Typical: 1469 W

● Static: 516 W

AC

RG-PA1200I-F

● Rated voltage: 110 V AC/220 V AC

● Rated voltage range: 100 V AC to 240 V AC, 50 Hz to 60 Hz

● Max voltage range: 90 V AC to 264 V AC, 47 Hz to 63 Hz

High-voltage DC

Input voltage range: 180 VDC to 300 VDC

Environment and Reliability

RG-S6920-4C

Operating Temperature

0ºC to 40ºC (32ºF to 104ºF)

Storage temperature

-40 °C to +70 °C (-40 °F to +158 °F)

Operating Humidity

10% RH to 90% RH (Non-condensing)

Storage humidity

5% to 95% RH (non-condensing)

Working altitude

Operating altitude: up to 5000 m (16,404.20 ft.)

Storage altitude: up to 5000 m (16,404.20 ft.)

 

Software Specifications

Software Specifications

RG-S6920-4C

L2 Protocols

IEEE802.3ad (Link Aggregation Control Protocol), IEEE802.1p, IEEE802.1Q, IEEE802.1D (STP), IEEE802.1w (RSTP), IEEE802.1s (MSTP), IGMP Snooping, MLD Snooping, Jumbo Frame (9 KB), IEEE802.1ad (QinQ and selective QinQ), GVRP

L3 Protocols (IPv4)

BGP4, OSPFv2, RIPv1, RIPv2, MBGP, LPM Routing, Policy-based Routing (PBR), Route-policy, Equal-Cost Multi-Path Routing (ECMP), WCMP, VRRP, IGMP v1/v2/v3, DVMRP, PIM-SSM/SM/DM, MSDP, Any-RP

IPv6 Basic Protocols

Neighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS

IPv6 Features

Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+, MLDv1/v2, PIM-SMv6, manual tunnel and IPv4 over IPv6 tunnel

Data Center Features

PFC, ECN, and other data center features

M-LAG

RDMA

OpenFlow 1.3

Visualization

gRPC

sFLOW sampling

INT

ACL

Standard IP-based ACL、Extended MAC-based ACL、Extended IP-bsaed ACL、Expert-level ACL、ACL 80、IPv6 ACL、Ingress/Egress ACLs、ACL Logging、ACL Counter (Ingress and egress counters are supported in interface or global configuration modes)、ACL Re-marking、Global ACL、ACL-based Redirection、Displaying ACL Resources、Processing First Packet of TCP Handshake When Binding the ACL to Restrict SIP、Matching Against 5-Tuple of Pass-by VXLAN Inner IP Packets、The expert-level ACL supports matching the IP flag and DSCP fields of VXLAN inner packets

QoS

Mapping of IEEE 802.1p, DSCP, and ToS priorities
ACL-based traffic classification
Priority marking/remarking
Multiple queue scheduling mechanisms, including SP, WRR, DRR, SP+WRR, and SP+DRR
Congestion avoidance mechanisms such as WRED and tail discarding

HA Design

GR for RIP/OSPF/BGP, BFD, DLDP, REUP dual-link fast switching, RLDP unidirectional link detection, 1+1 power redundancy and fan redundancy, and hot swapping for all cards and power supply modules

Security Features

Network Foundation Protection Policy (NFPP), CPP, DDoS attack defense, illegitimate data packet detection, data encryption, source IP spoofing prevention, IP scanning prevention, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, RIPv2, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, uRPF, broadcast packet suppression, DHCP Snooping, ARP spoofing prevention, ARP check, and hierarchical user management

Management Mode

SNMP v1/v2c/v3, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, Syslog, SPAN/RSPAN/ERSPAN, ZTP, NETCONF, Python, fan and power alarm function, temperature alarm function, and configuration rollback

Other Protocols

DHCP Client, DHCP Relay, DHCP Server, DNS Client, UDP relay, ARP Proxy, and Syslog

 

Safety and Regulatory Compliance

Specification

RG-S6920-4C

Safety

● IEC 62368-1

● EN 62368-1

● EN IEC 62368-1

● BS EN IEC 62368-1

● UL 62368-1

● CSA C22.2#62368-1

● GB 4943.1

Electromagnetic Compatibility (EMC)

● EN 55032

● EN 55035

● EN IEC 61000-3-2

● EN IEC 61000-3-3

● EN 61000-3-3

● ETSI EN 300 386

● EN 300 386

● ICES-003 Issue 7

● ICES-003 Issue 6

● ANSI C63.4-2014

● FCC CFR Title 47, Part 15, Subpart B

● AS/NZS CISPR 32

● CISPR 32

● GB/T 9254.1

Environment

● 2011/65/EU EN 50581

● 2012/19/EU EN 50419

● (EC) No.1907/2006

● GB/T 26572

*For more country-specific regulatory information and approvals, contact your local sales agency.

Show More
Resources All Resources
Learn about Products or Solutions
Order Information

The configuration procedure for the RG-S6920-4C switch is as follows:

  • Select the switch.
  • Select expansion modulesbased on business requirements.
  • Select the fan and power supply modules.
  • Select Optical Transceivers based on port requirements.

    Chassis, Fan, and Power Supply Modules

    Product Model

    Description

    RG-S6920-4C

    Four expansion slots, four power supply module slots, and six fan module slots
    The power supply module model is RG-PA1200I-F and the fan model is M2EFAN I-F.

    RG-PA1200I-F

    Power supply module, supporting 2+2 redundancy, hot swapping, and front-to-rear ventilation design

    M2EFAN I-F

    Fan module, supporting 5+1 redundancy, hot swapping, and front-to-rear ventilation design

     

    Expansion Modules

    Product Model

    Description

    M6900-32CQ

    32 x 100GE ports

    M6900-16CQ4QC

    16 × 100GE optical ports (QSFP28) + 4 × 400GE optical ports (QSFP-DD)

     

    400GBASE Series Optical Modules

    Product Model

    Description

    400G-QDD-DR4-SM1310

    400G DR4 module, QSFP-DD form factor, MPO-12 APC, 1310 nm, 500 m (1,640.42 ft.) over SMF

    400G-QDD-FR4-SM1310

    400G FR4 module, QSFP-DD form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF

    400G-QDD-SR8-MM850

    400G SR8 module, QSFP-DD form factor, MPO-16 APC, 850 nm, 100 m (328.08 ft.) over MMF

     

    100GBASE Series Optical Modules

    Product Model

    Description

    100G-QSFP-SR-MM850

    100G SR module, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over MMF

    100G-QSFP-iLR4-SM1310

    100G iLR4 module, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF

    100G-QSFP-LR4-SM1310

    100G LR4 module, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF

    100G-QSFP-ER4-SM1310

    100G ER4 module, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.59 ft.) over SMF

    100G-AOC-10M

    100G QSFP28 AOC cable, 10 m (32.81 ft.)

    100G-AOC-5M

    100G QSFP28 AOC cable, 5 m (16.40 ft.)

     

    40GBASE Series Optical Modules

    Product Model

    Description

    40G-QSFP-iLR4-SM1310

    40G iLR4 module, QSFP+ form factor, Duplex LC, 2 km (6,561.68 ft.) over SMF

    40G-QSFP-LR4-SM1310

    40G LR4 module, QSFP+ form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF

    40G-QSFP-LSR-MM850

    40G LSR module, QSFP+ form factor, MPO, 400 m (1,312.34 ft.) over MMF

    40G-QSFP-SR-MM850

    40G SR module, QSFP+ form factor, MPO, 150 m (492.13 ft.) over MMF

    40G-QSFP-LX4-SM1310

    40G LX4 module, QSFP+ form factor, Duplex LC connector, 150 m (492.13 ft.) over OM3/OM4 MMF, or 2 km (6,561.68 ft.) over SMF

    40G-AOC-30M

    40G QSFP+ AOC cable, 30 m (98.43 ft.)

    40G-AOC-5M

    40G QSFP+ AOC cable, 5 m (16.40 ft.)

Show More
How would you rate your experience on this page?
Very disatisfying
Very satisfying
If you would like to offer more comment, please type in the textbox below, that would be helpful for the improvement of this page.
Submit
Thank you for your feedback!

Ruijie Networks websites use cookies to deliver and improve the website experience.

See our cookie policy for further details on how we use cookies and how to change your cookie settings.

Cookie Manager

When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.

  • Performance cookies

    Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.

  • Essential cookies

    This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.

Accept All

View Cookie Policy Details

ติดต่อเรา

ติดต่อเรา

How can we help you?

ติดต่อเรา

Get an Order help

ติดต่อเรา

Get a tech support

2024 Ruijie Networks Brand Awareness Survey

Your opinions and feelings are crucial for our improvement.

Fill in the survey