Diverse access rates of 10 Gbps/5 Gbps/2.5 Gbps/1 Gbps/100 Mbps and 4 x 25GE SFP28 ports for uplink, enabling flexible networking and high-performance campus networks
Models
Series
Highlight Features
Hardware Specifications |
RG-CS86-24MG4VS-UP |
RG-CS86-48MG4VS2QXS-UPD |
RG-CS86-24XMG4XS4VS-UPD |
RG-CS86-12XMG4VS-UP |
Interface Specifications |
||||
Fixed port |
24 x 100M/1000M/2.5GE/5GE electrical ports with auto-negotiation |
48 x 100M/1000M/2.5GE/5GE electrical ports with auto-negotiation |
24 x 100M/1000M/2.5GE/5GE/10GE electrical ports with auto-negotiation 4 x 1GE/10GE SFP+ ports 4 x 10GE/25G SFP28 ports |
12 x 100M/1000M/2.5GE/5GE/10GE electrical ports with auto-negotiation 4 x 10GE/25G SFP28 ports |
Fan module |
2 fixed fans |
3 modular fans |
3 modular fans |
2 fixed fans |
Power module |
1 Built-in power module |
2 replaceable hot-swappable power supply slots |
2 replaceable hot-swappable power supply slots |
1 Built-in power module |
Fixed management port |
1 x MGMT port 1 x console port 1 x USB port |
1 x MGMT port 1 x console port 1 x USB port |
1 x MGMT port 1 x console port 1 x USB port |
1 x MGMT port 1 x console port 1 x USB port |
System Specifications |
||||
Packet forwarding rate |
327 Mpps |
625 Mpps |
565 Mpps |
327 Mpps |
Switching capacity |
440 Gbps/2.56Tbps |
840 Gbps/2.56Tbps |
760Gbps/2.56Tbps |
440 Gbps/2.56Tbps |
MAC address table size |
32,768 |
|||
ARP table size |
16,000 |
|||
Number of IPv4 unicast routes |
16,000 |
|||
Number of IPv4 multicast routes |
4,000 |
|||
Number of IPv6 unicast routes |
16,000 |
|||
Number of IPv6 multicast routes |
2,000 |
|||
Number of ACEs |
Ingress: 2,500 Egress:1,000 |
|||
Number of VSU members |
2 |
|||
Dimensions and Weight |
||||
Dimensions (W x D x H) |
442 × 220 × 43.6 mm (17.40 × 29.92 × 6.89 in.) , 1 RU |
442 × 220 × 43.6 mm (17.40 × 29.92 × 6.89 in.) , 1 RU |
442 × 220 × 43.6 mm (17.40 × 29.92 × 6.89 in.) , 1 RU |
442 × 220 × 43.6 mm (17.40 × 29.92 × 6.89 in.) , 1 RU |
Weight |
3.65 kg (8.82 lbs) |
6.11 kg (13.47 lbs) |
6.11 kg (13.47 lbs) |
3.65 kg (8.82 lbs.) |
CPU and Storage |
||||
CPU |
ARM processor, 1.25 GHz |
ARM processor, 1.25 GHz |
ARM processor, 1.25 GHz |
ARM processor, 1.25 GHz |
Flash memory |
1 GB |
1 GB |
1 GB |
1 GB |
BootROM |
16 MB |
16 MB |
16 MB |
16 MB |
SDRAM |
1 GB |
1 GB |
1 GB |
1 GB |
Data packet buffer |
4 MB |
4 MB |
4 MB |
4 MB |
Power Supply and Consumption |
||||
Maximum power consumption |
Without PoE: < 120 W (Total power consumption of all modules) Full PoE load: < 370 W |
Without PoE: < 240 W (Total power consumption of all modules) Full PoE load: < 1600 W |
Without PoE: < 120 W (Total power consumption of all modules) Full PoE load: < 1650 W |
Without PoE: < 120 W (Total power consumption of all modules) Full PoE load: < 370 W |
Maximum output power |
460W |
RG-PA600I-P-F: 600 W RG-PA1000I-P-F: 1000 W (Input Voltage: 176 V AC to 290 V AC or 190 V DC to 290 V DC) 930 W (Input Voltage: 90 V AC to 176 V AC, 176 V AC not included) |
RG-PA600I-P-F: 600 W RG-PA1000I-P-F: 1000 W (Input Voltage: 176 V AC to 290 V AC or 190 V DC to 290 V DC) 930 W (Input Voltage: 90 V AC to 176 V AC, 176 V AC not included) |
460W |
Rated Input Voltage |
Built-in power module Rated voltage range: 100 V AC to 240 V AC |
Available model: RG-PA600I-P-F Rated voltage range: 100 V AC to 240 V AC Available model: RG-PA1000I-P-F Rated voltage range: 100 V AC to 240 V AC |
Available model: RG-PA600I-P-F Rated voltage range: 100 V AC to 240 V AC Available model: RG-PA1000I-P-F Rated voltage range: 100 V AC to 240 V AC |
Built-in power module Rated voltage range: 100 V AC to 240 V AC |
Maximum input voltage |
Built-in power module Maximum voltage range: 90 V AC to 264 V AC |
Available model: RG-PA600I-P-F Maximum voltage range: 90 V AC to 264 V AC Available model: RG-PA1000I-P-F Maximum voltage range: 90 V AC to 264 V AC |
Available model: RG-PA600I-P-F Maximum voltage range: 90 V AC to 264 V AC Available model: RG-PA1000I-P-F Maximum voltage range: 90 V AC to 264 V AC |
Built-in power module Maximum voltage range: 90 V AC to 264 V AC |
PoE-capable Port |
Ports 1 to 24 support PoE/PoE+ and HPoE power supply |
Ports 1 to 48 support PoE/PoE+ power supply |
Ports 1 to 24 support PoE/PoE+ and HPoE power supply |
Ports 1 to 12 support PoE/PoE+ and HPoE power supply Maximum output power of a HPoE-capable port: 90 W |
Environment and Reliability |
||||
MTBF |
22.18 years |
27.02 years |
22.18 years |
22.18 years |
Primary airflow |
Front/Left-to-rear airflow |
Front/Left-to-rear airflow |
Front/Left-to-rear airflow |
Front/Left-to-rear airflow |
Operating Temperature |
0°C to 45°C (32°F to 113°F) |
0°C to 45°C (32°F to 113°F) |
0°C to 45°C (32°F to 113°F) |
0°C to 45°C (32°F to 113°F) |
Storage Temperature |
–40°C to +70°C (–40°F to +158°F) |
–40°C to +70°C (–40°F to +158°F) |
–40°C to +70°C (–40°F to +158°F) |
–40°C to +70°C (–40°F to +158°F) |
Operating Humidity |
10% RH to 90% RH (non-condensing) |
10% RH to 90% RH (non-condensing) |
10% RH to 90% RH (non-condensing) |
10% RH to 90% RH (non-condensing) |
Storage Humidity |
5% RH to 95% RH (non-condensing) |
5% RH to 95% RH (non-condensing) |
5% RH to 95% RH (non-condensing) |
5% RH to 95% RH (non-condensing) |
Surge Protection |
6 kV |
6 kV |
6 kV |
6 kV |
Temperature Monitoring |
Temperature alarm |
Temperature alarm |
Temperature alarm |
Temperature alarm |
Software Specifications |
RG-CS86-24MG4VS-UP |
RG-CS86-48MG4VS2QXS-UPD |
RG-CS86-24XMG4XS4VS-UPD |
RG-CS86-12XMG4VS-UP |
Ethernet switching |
Jumbo frame (maximum length: 9216 bytes) |
|||
IEEE 802.1Q (supporting 4K VLANs) |
||||
Voice VLAN |
||||
Super VLAN, Private VLAN |
||||
MAC VLAN, Port based VLAN, Protocol based VLAN, IP-Subnet based VLAN |
||||
GVRP |
||||
Basic QinQ Flexible QinQ |
||||
STP, RSTP, and MSTP |
||||
ERPS (G.8032) |
||||
LLDP/LLDP-MED |
||||
LACP (IEEE 802.3ad) |
||||
IP service |
ARP |
|||
DHCP client, DHCP relay, and DHCP server |
||||
DHCP snooping |
||||
DNS |
||||
DHCPv6 client and DHCPv6 relay |
||||
DHCPv6 snooping |
||||
Neighbor Discovery (ND) and ND snooping |
||||
IP Routing |
Static routing |
|||
RIP and RIPng |
||||
OSPFv2, OSPFv3, IS-ISv4, ISv4, and IS-ISv6 |
||||
BGP4 and BGP4+ |
||||
IPv4 and IPv6 PBR |
||||
ECMP |
||||
Multicast |
IGMP v1/v2/v3, and IGMP proxy |
|||
IGMP v1/v2/v3 snooping |
||||
PIM-DM, PIM-SM, and PIM-SSM |
||||
MSDP |
||||
MLD v1/v2 |
||||
MLD snooping v1/v2 |
||||
PIM-SMv6 and PIM-SSM v6 |
||||
ACL and QoS |
Standard IP ACLs Extended IP ACLs Extended MAC ACLs Time-based ACLs Expert-level ACLs ACL80 IPv6 ACL |
|||
Port traffic rate limiting |
||||
Congestion management: RR, SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ |
||||
Congestion avoidance: tail drop, RED, and WRED |
||||
802.1p/DSCP/ToS traffic classification Eight priority queues per port |
||||
Security |
Multiple AAA modes |
|||
RADIUS and TACAS+ |
||||
Port-based and MAC-based 802.1x authentication |
||||
Web authentication |
||||
HTTPS |
||||
SSHv1, SSHv2 |
||||
Global IP-MAC binding |
||||
IP source guard |
||||
SAVI |
||||
CPP and NFPP |
||||
Strict and loose RPF uRPF ignoring default routes |
||||
Reliability |
REUP, RLDP, DLDP |
|||
IPv4 VRRP v2/v3 and IPv6 VRRP |
||||
BFD |
||||
GR for RIP, OSPF, BGP |
||||
1+1 power redundancy |
||||
Hot swapping of power and fan modules |
||||
Device virtualization |
Virtual Switching Unit (VSU) |
|||
NMS and maintenance |
SPAN, RSPAN, and ERSPAN |
|||
sFLOW |
||||
NTP and SNTP |
||||
FTP and TFTP |
||||
SNMP v1/v2/v3 |
||||
RMON (1, 2, 3, 9) |
||||
NETCONF |
||||
CWMP (TR-069) standard protocol |
||||
gRPC |
||||
Cloud and SON |
||||
PoE |
IEEE 802.3af, 802.3at and 802.3bt Uninterruptible power supply upon hot start Port priority |
Follow the steps to order a RG-CS86 multi-GE switch:
Models marked with asterisks (*) in the ordering information are available later.
Model |
Description |
RG-CS86-24MG4VS-UP |
24 x 100M/1000M/2.5GE/5GE electrical ports with auto-negotiation fixed AC power supply and fan |
RG-CS86-48MG4VS2QXS-UPD |
48 x 100M/1000M/2.5GE/5GE electrical ports with auto-negotiation 4 x 10GE/25GE SFP28 + 2 x 40GE QSFP+ ports, support PoE/PoE+/PoE++(25-48 ports only support PoE/PoE+) 2 modular power supply slots (at least one RG-PA600I-P-F/ RG-PA1000I-P-F power module needed,no power module in default),3 modular fan slots (3 fan modules are equipped by default) |
RG-CS86-24XMG4XS4VS-UPD |
24 x 100M/1000M/2.5GE/5GE/10GE electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports , 4 x 10GE/25GE SFP28 ports,support PoE/PoE+/PoE++ 2 modular power supply slots (at least one RG-PA600I-P-F or RG-PA1000I-P-F power module needed,no power module in default),3 modular fan slots (3 fan modules are equipped by default) |
RG-CS86-12XMG4VS-UP |
12 x 100M/1000M/2.5GE/5GE/10GE electrical ports with auto-negotiation, 4 x 10GE/25GE SFP28 ports,support PoE/PoE+/PoE++ fixed AC power supply and fan |
RG-PA600I-P-F |
600 W AC power module |
RG-PA1000I-P-F |
1000 W AC power module |
Model |
Description |
Mini-GBIC-GT |
1000BASE-GT mini GBIC module |
MINI-GBIC-SX-MM850 |
1000BASE-SX, SFP transceiver, SM (850 nm, 500 m, LC). |
MINI-GBIC-LX-SM1310 |
1000BASE-LX, SFP transceiver, SM (1310 nm, 10 km, LC) |
MINI-GBIC-LH40-SM1310 |
1000BASE-LH, SFP transceiver, SM (1310 nm, 40 km, LC) |
MINI-GBIC-ZX80-SM1550 |
1000BASE-ZX80, SFP transceiver, SM (1550 nm, 80 km, LC) |
GE-SFP-LX20-SM1310-BIDI |
SFP BIDI Transceiver-TX1310/RX1550, 20 km, LC |
GE-SFP-LX20-SM1550-BIDI |
SFP BIDI Transceiver-TX1550/RX1310, 20 km, LC |
GE-SFP-LH40-SM1310-BIDI |
SFP BIDI Transceiver-TX1310/RX1550, 40 km, LC |
GE-SFP-LH40-SM1550-BIDI |
SFP BIDI Transceiver-TX1550/RX1310, 40 km, LC |
Model |
Description |
XG-SFP-SR-MM850 |
10GE SR, SFP+ transceiver, LC, 850-nm wavelength, applicable to SFP+ port |
XG-SFP-LR-SM1310 |
10GE LR, SFP+ transceiver, LC, 1310-nm wavelength, 10 km over SMF, applicable to SFP+ ports |
XG-SFP-ER-SM1550 |
10GE ER, SFP+ transceiver, LC, 1550-nm wavelength, 40 km over SMF, applicable to SFP+ ports |
XG-SFP-AOC1M |
10GE SFP+ active optical cable, 1 m, including one cable and two interface modules |
XG-SFP-AOC3M |
10GE SFP+ active optical cable, 3 m, including one cable and two interface modules |
XG-SFP-AOC5M |
10GE SFP+ active optical cable, 5 m, including one cable and two interface modules |
Model |
Description |
VG-SFP-SR-MM850 |
25GE SR, SFP28, 850-nm wavelength, 100 m over MMF |
VG-SFP-LR-SM1310 |
25GE LR, SFP28, 1310-nm wavelength, 10 km over SMF |
VG-SFP-AOC5M |
25GE SFP+ active optical cable, 5 m, including two modules |
Model |
Description |
40G-QSFP-SR-MM850 |
40GE SR, QSFP+ transceiver, applicable to QSFP+ ports |
40G-QSFP-LR4 SM1310 |
40GE LR4, QSFP+ transceiver, LC, 1310-nm wavelength, 2-core, 10 km over SMF, applicable to QSFP+ ports |
40G-AOC-5M |
40GE QSFP+ active optical cable, 5 m, including one cable and two interface modules |
40G-AOC-10M |
40GE QSFP+ active optical cable, 10 m, including one cable and two interface modules |
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
ติดต่อเรา
How can we help you?
Your opinions and feelings are crucial for our improvement.
Fill in the survey